| Specifications |
Falcon 8500SB |
Falcon 8500WB |
| Heating Zones |
5 |
5 |
| Cooling Zones |
2 |
1 |
| Load Zones |
1 |
N/A |
| Total Number of Zones |
8 |
6 |
| Platen Size |
8 in. W x 12 in. L |
8 in W x 12 in L |
| Minimum Substrate Size |
N/A |
3 inches |
| Maximum Substrate Size |
8 in. W x 11 in. L |
8 in W x 11 in L |
| Weight Limit |
N/A |
Approx. 2.5 lbs |
| Time Mode (Dwell & Travel Time) |
15 seconds to 99 min. 59 sec. (per zone) |
10 sec. – 99 min, 59 sec. |
| Temperature (Standard) |
Up to 420°C |
Up to 420C |
| Temperature Accuracy |
± 2°C |
+/- 2C |
| Warm-up Time to 230°C |
15 minutes |
15 min. approx. |
| Coolant Flow |
0.5 to 2 GPM |
.5 to 2 GPM |
| Alarms |
Over/Under Temperature, Gas Flow, Coolant Flow & Temperature, Motor Torque, SMEMA (or other) Interface |
Over/Under Temperature, Gas Flow, Coolant Flow and Temperature, Motor Torque, SMEMA (or other) Interface |
| Parts Flow (Specify When Ordering) |
In-Line: L to R or R to L |
L to R or R to L |
| Gas Consumption |
0-600 cubic feet/hour (process dependent) |
1000 CFH |
| O2 Level |
< 25 PPM (process dependent) |
<25 PPM (process dependent) |
| Voltage (Specify when Ordering) |
200 to 240 VAC, 50/60 Hz, 1 or 3 Phase |
200-240 VAC, 50-60 Hz, 1 or 3 Ph |
| Start-up Power (Kw) |
10 kW @ 240 VAC |
10kW @ 240 VAC |
| Power Consumption |
50% duty cycle or less |
50% Duty Cycle or less |
| Basic Unit Weight |
750 Lbs. |
750 lbs |
| Basic Unit Dimensions |
L 126 x W 28 x H 45 inches |
L 126 x W 28 x H 45 inches
L 140 with paddle adapters |