| Specifications |
Falcon 1200SB |
Falcon 1200WB |
| Heating Zones |
7 |
7 |
| Cooling Zone |
2 |
1 |
| Load Zones |
1 |
N/A |
| Total Number of Zones |
10 |
8 |
| Platen Size |
12.5 in. W X 13.5 in L. |
12.5 in W x 13.5 in L |
| Minimum Substrate Size |
N/A |
3 inches |
| Maximum Substrate Size |
12 in. W X 12 in. L x 0.9 in. H |
12 in W x 12 in L |
| Weight Limit |
N/A |
Approx. 2.5 lbs |
| Speed Mode (Inches per Minute |
1 in. to 80 in. per min. |
N/A |
| Time Mode (Dwell & travel Time) |
15 sec. To 99 min. 59 sec. (per Zone) |
16 sec. – 99 min, 59 sec. |
| Temperature (Standard) |
Up to 420°C |
Up to 420C |
| Temperature Accuracy |
±2°C |
+/- 2C |
| Warm-up Time to 230°C |
15 minutes (approx.) |
15 min. approx. |
| Coolant Flow |
0.5 to 2 GPM |
.5 to 2 GPM |
| Alarms |
Over/Under Temperature, Gas Flow, Coolant Flow & Temperature, Motor
Torque, SMEMA (or other) Interface |
Over/Under Temperature, Gas Flow, Coolant Flow and Temperature, Motor Torque, SMEMA (or other) Interface |
| Parts Flow (Specify) |
In-line: L to R or R to L |
L to R or R to L |
| Gas consumption |
0-800 cubic feet/hour (process dependent) |
1200 CFH |
| O2 Level |
<25 PPM (process dependent) |
<25 PPM (process dependent) |
| Voltage (Specify) |
200-240 VAC, 50-60 HZ, 3 phase |
200-240 VAC, 50-60 Hz, 3 Phase |
| Start-up Power |
33 Kw @ 240 VAC |
33 kW @ 240 VAC |
| Power Consumption |
50% duty cycle or less (process dependent) |
50% duty cycle or less (process dependent) |
| Basic Unit Weight |
1000 lbs. |
1000 lbs |
| Basic Unit Dimensions |
L 164 x W 24 X H 45 inches |
L 178 x W 24 x H 45 inches
L 178 with paddle adapters |