Home
Products
Samsung Products

RF30 Series
|
|
|
|
|
|
|
|
|
|
|
|
|

|
- Heating and cooling function
applicable for the lead-free
soldering of various boards
- Energy saving design considering
the global warming
- Compact design emphasizing
the productivity and
floor environment
- Flux recovery function that
increased the degree of
cleanliness of oven
exhausted air
- Added rich productivity
management information
for operation status, history
and output management
- Electrical wiring and structure
frame design that improve
the maintenance-ability.
|

Heating System |
 |
Air flow furnace with high heating efficiency is realized by adopting multi
heating zones so that it can be applicable for the various types of component
placement on board and at the same time by applying the nozzle structure for
which the air flow resistance is improved.
Multi heating zones and new air flow method allow the temperature profile with
stable wind speed.
Even the placement of components on the boards such as multi-layered board
or the board where components of high thermal capacity are mixed, which was
difficult to perform placement with existing reflow can be realized with
extremely little temperature difference between board and placed
component.
For small boards for portable equipment, the production
cost, roductivity, energy consumption can be reduced and
improved to a great extent by reducing the tack time. |
|
PC Control System |
 |
PC reflow with various functions
Reflow oven control
More improved and subdivided error message function
Convenient operation and handling through the
classification and indication of increased temperature zone,
reached temperature, etc. in colors according to the
temperature setup.
Graphic numerical control of setup temperature of each zone |
|
Designing of Maintenance |
 |
| Considering high efficiency, productivity and cost reduction, we have simplified the maintenance of
the blower motor, conveyor and cooling unit and improved the convenience of the operation through
efficient machine design and electrical wiring. |
|
For cooling and Flux Recovery System |
 |
Cooling and Flux Recovery System Cleans the exhaust air and re-duces the flux contaminants in the
¡°furnace¡± to a great degree by adopting newly developed high performance flux recovery unit.
In particular, the chiller type cooling increases the cooling speed to realize highly reliable soldering. |
|
|
|
|
|
|
| Model Name |
RF3082 |
RF30102 |
RF30122 |
RF3082N |
RF30102N |
RF30122N |
| Apparent Power (Kw) |
40kw |
46kw |
55kw |
42kw |
49kw |
58kw |
| |
Approximately 9.5kw |
Approximately 13kw |
Approximately 61kw |
Approximately 10kw |
Approximately 13kw |
Approximately 16kw |
| Operating Voltage (V) |
3Ø 380V 50Hz / 60Hz (3Ø 220V 50Hz / 60Hz) |
| Operating Current (A) |
61A(105A) |
70A(120A) |
83A(145A) |
64A(110A) |
75A(129A) |
88A(152A) |
| Outline Dimension (LxWxH) |
3,938×1,340×1,450 |
4,938×1,340×1,450 |
4,938×1,340×1,450 |
4,413×1,340×1,450 |
4,938×1,340×1,450 |
5,633×1,340×1,450 |
| Weight (kg) |
1,800(kg) |
2,000(kg) |
2,100(kg) |
2,500(kg) |
2,800(kg) |
3,000(kg) |
| Number of Heating Zones |
8 Zone |
10 Zone |
12 Zone |
8 Zone |
10 Zone |
12 Zone |
| Heating Zone Length (mm) |
2,200 |
2,700 |
3,200 |
2,200 |
2,700 |
3,200 |
| Number of Cooling Zones |
2 Zone |
2 Zone |
2 Zone |
2 Zone |
2 Zone |
2 Zone |
| Cooling Method |
Air Cooling |
Air Cooling |
Air Cooling |
N2 Atmosphere Cooling |
N2 Atmosphere Cooling |
N2 Atmosphere Cooling |
| Chiller(op) |
Chiller(op) |
Chiller(op) |
Chiller |
Chiller |
Chiller |
| PCB Transfer Speed |
0.3 ~ 1.6m/min |
| PCB Transfer Direction |
Left → Right(Right → Left) |
| Fixed Conveyer Rail |
Front Rail(Rear Rail) |
| PCB Dimension (mm) W |
50 ~ 410(500:Option) |
| Conveyor Belt Height (mm) |
885 ~ 920mm from floor(Normally 900mm) |
| PCB Conveying Method |
SUS #35 Chain 4mm Pin |
| Temperature Meter |
16ch |
20ch |
24ch |
16ch. |
20ch |
24ch |
| Hot Air Speed |
Approximately 0.5 ~ 4.0 m/sec at Pre-heater & Reflow |
| PCB Drop Detection |
Photo Sensor |
| PCB Stop Detection |
Photo Sensor |
| Auto Stop |
Stops after no-load operation for 30 minutes since the system is turned off |
| Oxygen Concentration Control |
- |
- |
- |
O2 Analyzer |
| Oxygen Concentration Indication |
- |
- |
- |
O2 Controller |
| Nitrogen Consumption |
- |
- |
- |
12 ~ 15㎥/h(Based on 500PPM) |
| Alarm Monitor |
PC Monitor Indication/Emergency Stop/
Conveyor Problem/Cover Opened/
Board Drop Alarm/Board Stop Alarm/
Abnormal Temperature Alarm/Thermal Alarm |
PC Monitor Indication/Emergency Stop/
Conveyor Problem/Cover Opened/
Board Drop Alarm/Board Stop Alarm/
Abnormal Temperature Alarm/Thermal Alarm/
Abnormal %, PPM/N2 Pressure |
| Others |
PC, UPS, Mesh Belt or Anti-warp Conveyor |
|
|
|
Top
Click here for more information or contact our offices in Vietnam:
© 2006-2010 AcroSemi Corporation. All rights reserved.
|