TIẾNG VIỆT | ENGLISH

Home Products Aqueous Technologies Products





Trident is a fully automatic defluxing and cleanliness testing system designed to remove all flux and solder paste residues from post reflowed circuit assemblies. Trident is capable of removing all flux types including Rosin, Water Soluble, and all No-Cleans. Trident is uniquely capable of removing all eutectic and lead-free residues either separately or mixed in the same batch.

Trident is equipped with the multiple award winning Focus-Wash cleaning technology. Focus-Wash directs more fluid flow to a concentrated area, resulting in greater impingement, even on densely populated, low standoff SMT assemblies. Trident’s exclusive oscallating board rack and counter-rotating spray arms reduce shadowing by ensuring complete spray coverage.

How and Why We build Trident
How To Load a Trident






Trident is equipped with real-time predictive cleanliness capabilities. The on-board cleanliness tester automatically controls the cleaning process, ensuring a cleanliness level that equals or exceeds your programmed setting. In many cases, Trident’s predictive cleanliness capability eliminates the need for off-line post defluxing cleanliness testing.

Trident is controlled by a powerful industrial computer running the exceptionally stable Windows CE platform. A large graphic touch-screen provides an intuitive operator interface. Operators may select program recipes from a drop-down list. Authorized supervisors and administrators with password privileges have additional access to the recipe editor and administrative functions. An on-board statistical process control (SPC) data logger automatically records vital process information such as cleanliness levels. SPC data may be viewed locally on the display screen, exported onto a USB device, or viewed remotely on any network-connected PC. Trident is equipped with a host of standard features such as stainless steel plumbing, pre-drain filtration system, stainless steel adjustable board rack, and much more.

Features Include:

• Windows CE Control
• 10.4" (264mm) Touchscreen Interface
• Built-In Cleanliness Tester
• Pre-Drain Filtration System
• Fastest Cycle Time in Class
• Powerful Heated Drying System
• SPC Data Logging and Review
• Password Protected Functions
• Available Chemical Management System
• Built-In DI Water Heater
• Adjustable ESD Safe Board Rack
• Award-Winning Focus-Wash Technology
• Wash Solution Level Gauges
• Front-Access Maintenance Bays
• Multi-Award Winning Technology
• Windows Networkable
• Segregated Spray and Drain Pumps





Trident Automatic Defluxing and Cleanliness Testing System is available in seven configurations:

  • Trident I (low or zero discharge)

  • Trident II (low or zero discharge)

  • Trident III (low discharge, zero discharge, closedloop)


  • Trident I: Trident I is capable of removing all flux residues including Rosin, NoClean, and Water Soluble. Both lead and leadfree flux residues may be removed using Trident I. Trident I is equipped with an automatic chemical injection system that automatically adds a programmable volume of defluxing chemical to the wash water. Wash solution is heated automatically and sprayed onto the assemblies. At the end of the wash cycle, the wash solution is directed through a stainless steel filter housing and drained from the machine. Rinse water is then sprayed onto the assemblies until the desired cleanliness level is achieved. All rinse water is directed through the predrain filtration system then sent to drain. Assemblies are dried via the onboard convection and radiant forced air drying system.

    Trident II: Trident II is capable of removing all flux residues including Rosin, NoClean, and Water Soluble. Both lead and leadfree flux residues may be removed using Trident II. Trident II is equipped with a closedloop wash solution recycling system. Wash solution is heated automatically and sprayed on the assemblies. At the end of the wash cycle, the wash solution is directed back to the wash solution holding tank for subsequent reuse. Rinse water is then sprayed onto the assemblies until the desired cleanliness level is achieved. All rinse water is directed through the predrain filtration system then sent to drain. Assemblies are dried via the onboard convection and radiant forced air drying system. An optional ZeroDischarge evaporation system eliminates connection to a drain line.

    Trident III: Trident III is capable of removing all flux residues including Rosin, NoClean, and Water Soluble. Both lead and leadfree flux residues may be removed using Trident III. Trident III is equipped with an automatic chemical injection system that automatically adds a programmable volume of defluxing chemical to the wash water. Trident III is equipped with a closedloop wash solution recycling system. Wash solution is heated automatically and sprayed onto the Automatic Defluxing + Cleanliness Testing + Drying assemblies. At the end of the wash cycle, the wash solution is directed back to the wash solution holding tank for subsequent reuse. Rinse water is then sprayed onto the assemblies until the desired cleanliness level is achieved. All rinse water is directed through the predrain filtration system then sent to drain. Assemblies are dried via the onboard convection and radiant forced air drying system. Trident III is equipped with a host of standard features including programmable maintenance reminders, remote SPC viewing, SPC data USB export, and an builtin chemical management system. An optional ZeroDischarge evaporation system eliminates connection to a drain line.

    Trident IIICL: Trident IIICL is capable of removing all postreflow watersoluble flux residues. Because it is closed loop, all water is captured, redeionized, and reused, eliminating the need for a drain connection. The CL configuration does not require a drain and automatically converts a user's tapwater in to highquality deionized water. The CL configuration is not compatible with cleaning applications which require chemical additives.

    Require High Throughput?

    Get out of Line and Get into Trident High-Yield

    Trident High Yield Models

        More throughput and process control than an inline defluxer
        Lower acquisition and operating cost than an inline defluxer
        More environmental responsible than an inline defluxer
        Less floor-space than an inline defluxer



    FEATURE Trident I Trident II Trident III Trident CL
    Dimensions 34” D x 44” W x 71” H 34” D x 44” W x 71” H 34” D x 44” W x 71” H 34” D x 44” W x 71” H
    Weight 800 lbs (362.87 kg) 800 lbs (362.87 kg) 800 lbs (362.87 kg) 800 lbs (362.87 kg)
    Power Requirements 208-240 VAC 40 amps 3Ø
    400 VAC 31 amps 3Ø
    208-240 VAC 40 amps 3Ø
    400 VAC 31 amps 3Ø
    208-240 VAC 40 amps 3Ø
    400 VAC 31 amps 3Ø
    208-240 VAC 40 amps 3Ø
    400 VAC 31 amps 3Ø
    Water Input ¾” NPT ¾” NPT ¾” NPT ¾” NPT (makeup water)
    Drain ¾” NPT ¾” NPT ¾” NPT N/A
    Air Exhaust 6” (static) 6” (static) 6” (static) 6” (static)
    ZeroDischarge Configuration Available? No Yes Yes N/A
    NoClean Flux Removal Yes Yes Yes No
    Water Soluble Flux Removal Yes Yes Yes Yes/TD>
    Rosin Flux Removal Yes Yes Yes No
    Lead and Lead-Free Compatible Yes Yes Yes Many
    Weight 800 lbs (362.87 kg 800 lbs (362.87 kg) 800 lbs (362.87 kg) 800 lbs (362.87 kg)
    Built-In Cleanliness Testing Standard Standard Standard Standard
    Discharge Configuration Filtered wash drain Filtered rinse drain Closed-loop wash Filtered rinse drain Closed-loop wash Filtered rinse drain Closed-loop (no drain)
    Closed-Loop Wash Solution Recycler NO Standard Standard Standard
    Weight 800 lbs (362.87 kg 800 lbs (362.87 kg) 800 lbs (362.87 kg) 800 lbs (362.87 kg)
    SPC Data Logging with On-Screen Viewing Standard Standard Standard Standard
    SPC Data USB Export Optional Optional Standard Standard
    SPC Remote Viewing Optional Optional Standard Standard
    Heated Drying System Standard Standard Standard Standard
    Pre-Drain Filtration System Standard Standard Standard N/A
    Programmable Maintenance Reminders Optional Optional Standard Standard
    Weight 800 lbs (362.87 kg 800 lbs (362.87 kg) 800 lbs (362.87 kg) 800 lbs (362.87 kg)
    Control System Windows CE computer with Intel XScale processor Windows CE computer with Intel XScale processor Windows CE computer with Intel XScale processor Windows CE computer with Intel XScale processor
    Operator Interface 10.4” (26.4cm) touchscreen 10.4” (26.4cm) touchscreen 10.4” (26.4cm) touchscreen 10.4” (26.4cm) touchscreen
    ESD Ground Point Standard Standard Standard Standard

    SPECIAL:




    For more information, please visit http://www.aqueoustech.com/trident.html